NUMERICAL SIMULATION OF OPERATION OF A PRESSURE-OPERATED SEASONAL COOLING DEVICE WITH SEVERAL EVAPORATION UNITS
G.V. Anikin1, S.N. Plotnikov2
1Earth Cryosphere Institute, Tyumen Scientific Centre Siberian Branch of Russian Academy of Sciences, Tyumen, Russia 2Technomonitoring LCC, Tyumen, Russia
Keywords: permafrost, pressure seasonal cooling device, carbon dioxide, thermal stabilization, numerical modeling
Abstract
In this article, a numerical simulation of a pressure seasonal cooling device with several evaporation units is considered. The simulation was performed using the example of three new-type evaporation units connected to a single condenser. The operating parameters were determined for different depths of evaporation units in the ground (12, 20, and 30 m), which are most often used in real practice for thermal stabilization of soils. Numerical experiments demonstrate that this device functions efficiently under significant variations in key external conditions, such as ambient temperature, even under extreme values of specific thermal loads on the evaporator of the seasonal cooling device. The operating parameters of this seasonal cooling device are: evaporator temperature, liquid and gas mass flows in the evaporator, and the true gas content at the evaporator outlet. The dynamics of refrigerant temperature changes in the evaporator depending on the condenser temperature, specific thermal loads, and depths of the evaporation units attest to the ability of the device to maintain the required temperature regime in frozen soils.
|