Publishing House SB RAS:

Publishing House SB RAS:

Address of the Publishing House SB RAS:
Morskoy pr. 2, 630090 Novosibirsk, Russia



Advanced Search

Atmospheric and Oceanic Optics

2018 year, number 7

Metrological control of the spatial positions of elements of the “Millimetron” telescope primary mirror

V.V. Sychev1, A.I. Klem1,2
1Bauman Moscow State Technical University, 2-ya Baumanskaya str., 5/1, 105005, Moscow, Russia
2Astro Space Center, P.N. Lebedev Physical Institute of the Russian Academy of Science, 53 Leninskij Prospekt, 119991, Moscow, Russia
Keywords: космический телескоп, система адаптивного управления, датчик углового рассогласования, составное главное зеркало, space telescope, adaptive control system, sensor of angular misalignment, composite primary mirror

Abstract

Possible variants of the sensor equipment based on the pseudo-circulation of the wave front of the measuring beam and photoelectronic-optics amplification of the angular misalignment signal are considered. Evaluation of the characteristics of these sensors allows us to conclude a possibility of creating measuring systems that meet the requirements of the “Millimetron” telescope.