Third heat transfer crisis at subcooling
B.P. Avksentyuk1, V.V. Ovchinnikov2
1 Vinnitsa Institute of Trade and Economics of Kiev National University of Trade and Economics, Vinnitsa, Ukraine 2 Kutateladze Institute of Thermophysics SB RAS, Novosibirsk, Russia
Pages: 267-274
Abstract
The effect of liquid subcooling below the saturation temperature on the third heat transfer crisis was studied experimentally at pool boiling. Experimental data on the threshold values of superheating and heat fluxes, above which the evaporation front and third heat transfer crisis for acetone at subcooling from 0.3 to 10 K are formed, were shown. Formation of evaporation fronts is the necessary, but not sufficient condition for the third heat transfer crisis at subcooling. It was found that formation of a stable vapor film after propagation of condensation fronts over the heater surface is possible at heat fluxes considerably lower than the first critical one.
|