Thermal capacity of liquid freon R-236ea
A.V. Baginsky, S.V. Stankus, and A.S. Kosheleva
Kuteteladze Institute of Thermophysics SB RAS, Novosibirsk, Russia
Pages: 627-630
Abstract
Thermal capacity Cp of liquid 1,1,2,3,3,3-hexafluoropropane (R-236ea) is measured by the method of high-frequency heat waves within the temperature range from 264 to 354 K and at pressures up to 31.7 bar. Thermal capacity of liquid (Cps) is calculated at the liquid-vapor equilibrium line. Dependencies Cp(P,T) and Cps(T) are suggested.
|