The
article presents the results of experimental studies of the influence of
different designs of mixing spacer grids on the coolant flow in FA-KVADRAT PWR.
The investigations were carried out by simulating the coolant flow in the core
on the experimental air stand being an aerodynamic open loop through which air
is pumped. To measure the local hydrodynamic characteristics of the
coolant flow, special pneumometric sensors were used for measuring
the total velocity vector and the flow rate value. During the
investigations of the local hydrodynamics of the coolant, transverse flow
velocity, as well as the coolant flow rates in the cells of the experimental
model FA-KVADRAT, was measured. The analysis of spatial distribution of
projections of absolute flow velocity allowed studying and detailing the
coolant flow pattern behind the mixing spacer grids with different designs of
deflectors as well as selecting the op-timal design of the deflector. The
accumulated database on the coolant flow in FA-KVADRAT has formed
the basis for engineering assessment of active zones’ structures of PWR.
The results of experimental studies are used to verify CFD codes (in both
foreign and domestic development) as well as programs for detailed cell-by-cell
calculation of active zones in order to reduce conservatism when assessing heat
engineering reliability.