Gas flow from a supersonic nozzle with screen into vacuum
V.N. Yarygin, V.G. Prikhodko, P.А. Skovorodko , and I.V. Yarygin
Kutateladze Institute of Thermophysics SB RAS, Novosibirsk, Russia E-mail: yarygin@itp.nsc.ru
Keywords: supersonic nozzle, flow into vacuum, backflow, gas-dynamic protective devices
Pages: 937–940
Abstract
The backflow formation
under gas outflow from the supersonic nozzle into vacuum was studied in
detail both experimentally and numerically. Possibilities of backflow control
(minimization) by using the gas-dynamic protective devices (screens)
mounted at the nozzle outlet were discussed. It was shown that certain
screen configurations can increase the backflow instead of decreasing it.
DOI: 10.1134/S0869864316060172
|