A two-loop frequency-domain electromagnetic induction system for detection of anomalous objects
						
						A.I. Chelovechkov, B.M. Chistoserdov, S.V. Baidikov 
						Institute of Geophysics, Uralian Branch of the RAS, 100 ul. Amundsena, Ekaterinburg, 620016, Russia 
													Keywords: Two-loop measurement system; field focussing; frequency-domain electromagnetic induction sounding 
												Pages: 628-633 						Subsection: GEOPHYSICS 
																					 Abstract 
								We discuss a two-loop frequency-domain electromagnetic induction sounding system which allows vertical focussing of the primary magnetic field thus reducing the disturbance from shallow subsurface. The frequency dependence of apparent resistivity estimated from the real part of the measured magnetic field turns out to be more sensitive than that found from the absolute total field. The advantage of the suggested FD EMI system has been validated by experiments. 
																			                        																														
					 |