Water injection into a geothermal reservoir
V. Sh. Shagapov, U. R. Il'yasov,* and L. A. Nasyrova**
Institute of Mechanics, Ufa Scientific Center, Russian Academy of Sciences, Ufa 450025; *Sterlitamak State Pedagogical Institute, Sterlitamak 450103; **Ufa Technological Institute of Service, Ufa 450000
Pages: 593-602
Abstract
The previously obtained criterion which
distinguishes water injection regimes
accompanied by vaporization of injected
water or vapor condensation is extended
to the radially symmetric problem. The
effects of cold liquid injection rate
and the initial temperature, pressure,
and capacity of a geothermal reservoir
on hydrodynamic and temperature profiles
are examined.
|